EPCON is the electro-pneumatic controller of BY Controls (Gimhae, Korea), in production since 1998 and fitted on a large number of Korean-built vessels to drive temperature and pressure control valves. LIMANNTECH supplies genuine EPCON units and spare parts worldwide.
Request a quotationContact us
How EPCON works
EPCON combines an electronic digital controller and a pneumatic output stage in one housing. It reads the 4–20 mA signal of a temperature or pressure transmitter, compares it with the set point and sends an air signal straight to the control valve actuator. Because the pneumatic stage is built in, the loop needs no separate positioner or I/P converter: only the control valve, the controller, an air filter regulator, the transmitter and a power supply.
General specification
| Item | EPCON |
|---|---|
| Power supply | 110 / 220 V AC, 50 / 60 Hz, or 24 V DC |
| Power consumption | 10 W max., 9 W steady state |
| Input | 4–20 mA |
| Output | 4–20 mA standard, 5% span accuracy |
| Control action | Direct or reverse |
| Control method | P, PI, PID |
| Local set point | Push-button switches and digital display |
| Remote set point | 4–20 mA standard input |
| Display | Process value (PV), set point (SP) |
| Air input | 2.4 ± 0.1 bar (35 ± 1.5 psi) |
| Air output | 0.4–2.0 bar (6–30 psi) |
| Air consumption | Zero at steady state |
| Accuracy | 0.5% of full span |
| Ambient temperature | -20 to 60 °C |
| Dimensions | 228 (W) × 295 (H) × 149 (D) mm |
| Enclosure / material | IP44 / polycarbonate |
Typical applications
- Jacket cooling water and lube oil temperature control with TG / TR 3-way valves
- Steam pressure and heating steam control with DP / DG 2-way valves
- Replacement of a failed controller on vessels in service
- Upgrade from a pneumatic BPCON loop where remote monitoring is wanted
How to order
Send the details
Nameplate photo, model and serial number, size and rating, vessel name or hull number.
Quotation in 24 hours
We confirm the exact genuine part against the maker's record and reply within one working day.
Delivery
To vessels in Busan and other Korean ports, or worldwide by air and sea freight.
FAQ
What information is needed to quote an EPCON controller?
A photo of the controller nameplate, the supply voltage, the vessel name or hull number and the tag number of the control valve it operates.
Is a positioner needed with EPCON?
No. EPCON sends the air signal directly to the actuator, so a separate positioner or I/P converter is not required.
Does EPCON consume instrument air continuously?
No. Air consumption is zero at steady state; air is used only while the output is changing.
More BY Controls products
BPCON & PLCONPneumatic controllers
DP & DG Control Valves2-way control valves
TG & TR Temperature Control Valves3-way temperature control
VRCS & Hydraulic ActuatorsValve remote control
HYDECKManual hydraulic remote control
Cryogenic ValvesLNG service
Watertight Doors & HatchesDoors, pilot doors, hatches