BY Controls HYDECK – Manual Hydraulic Remote Valve Control
HYDECK is the manual hydraulic remote valve control of BY Controls, in production since 1982. A valve in a tank or void space is opened and closed by a handwheel on deck, with no electric power and no hydraulic power unit. LIMANNTECH supplies genuine HYDECK transmitters, actuators and spares.
Request a quotationContact us
How HYDECK works
The system has two parts: a transmitter placed where the operator can reach it, and an actuator mounted on the valve. They are joined by a pair of small tubes, one for opening and one for closing. Turning the handwheel clockwise drives a small ball piston pump that pressurises the closing line; turning it counter-clockwise pressurises the opening line, and the return oil flows back to the tank inside the transmitter.

Transmitter
| Size | T12 | T20 | T24 | T26 |
|---|---|---|---|---|
| Pumping rate (cc/rev) | 12 | 24 | 48 | 67 |
- Built-in safety relief valve: the handwheel can keep turning at the end of travel without damage
- Valve position indicator on the transmitter
- Self-seal couplings for emergency operation with an external hand pump
- Can be installed in any position
Actuators
- Rotary actuators (rack and pinion or scotch yoke) for butterfly and ball valves
- Linear actuators for globe and gate valves
- Optional lock valve that holds the valve position if a tube is damaged
- Emergency local manual operation
Spare parts we supply
- Complete transmitters and actuators
- Seal kits and O-rings
- Lock valves, relief valves, self-seal couplings
- Position indicator parts
For powered systems see the BY Controls VRCS page.
How to order
Send the details
Nameplate photo, model and serial number, size and rating, vessel name or hull number.
Quotation in 24 hours
We confirm the exact genuine part against the maker's record and reply within one working day.
Delivery
To vessels in Busan and other Korean ports, or worldwide by air and sea freight.
FAQ
The valve does not move fully when the handwheel is turned. What should be checked?
Air in the lines is the usual cause. Purge the actuator as described in the maker's manual and check the oil level in the transmitter tank. If the tubing is damaged, the lock valve holds the valve position until the line is repaired.
What is needed to quote HYDECK spares?
Transmitter size (T12, T20, T24 or T26), actuator nameplate, valve size and the vessel name or hull number.
More BY Controls products
EPCON ControllerElectro-pneumatic controller
BPCON & PLCONPneumatic controllers
DP & DG Control Valves2-way control valves
TG & TR Temperature Control Valves3-way temperature control
VRCS & Hydraulic ActuatorsValve remote control
Cryogenic ValvesLNG service
Watertight Doors & HatchesDoors, pilot doors, hatches