BY Controls HYDECK – Manual Hydraulic Remote Valve Control

HYDECK is the manual hydraulic remote valve control of BY Controls, in production since 1982. A valve in a tank or void space is opened and closed by a handwheel on deck, with no electric power and no hydraulic power unit. LIMANNTECH supplies genuine HYDECK transmitters, actuators and spares.

Request a quotationContact us
BY Controls HYDECK transmitter stand
TransmittersT12 / T20 / T24 / T26
OilISO VG 22–32
Oil temperature-25 to 90 °C
PowerNone required

How HYDECK works

The system has two parts: a transmitter placed where the operator can reach it, and an actuator mounted on the valve. They are joined by a pair of small tubes, one for opening and one for closing. Turning the handwheel clockwise drives a small ball piston pump that pressurises the closing line; turning it counter-clockwise pressurises the opening line, and the return oil flows back to the tank inside the transmitter.

BY Controls HYDECK transmitter

Transmitter

SizeT12T20T24T26
Pumping rate (cc/rev)12244867
  • Built-in safety relief valve: the handwheel can keep turning at the end of travel without damage
  • Valve position indicator on the transmitter
  • Self-seal couplings for emergency operation with an external hand pump
  • Can be installed in any position

Actuators

  • Rotary actuators (rack and pinion or scotch yoke) for butterfly and ball valves
  • Linear actuators for globe and gate valves
  • Optional lock valve that holds the valve position if a tube is damaged
  • Emergency local manual operation

Spare parts we supply

  • Complete transmitters and actuators
  • Seal kits and O-rings
  • Lock valves, relief valves, self-seal couplings
  • Position indicator parts

For powered systems see the BY Controls VRCS page.

How to order

1

Send the details

Nameplate photo, model and serial number, size and rating, vessel name or hull number.

2

Quotation in 24 hours

We confirm the exact genuine part against the maker's record and reply within one working day.

3

Delivery

To vessels in Busan and other Korean ports, or worldwide by air and sea freight.

FAQ

The valve does not move fully when the handwheel is turned. What should be checked?

Air in the lines is the usual cause. Purge the actuator as described in the maker's manual and check the oil level in the transmitter tank. If the tubing is damaged, the lock valve holds the valve position until the line is repaired.

What is needed to quote HYDECK spares?

Transmitter size (T12, T20, T24 or T26), actuator nameplate, valve size and the vessel name or hull number.