Mt.H Hydrogen Valves – 99.9 MPa Gas and Liquid Hydrogen
Ultra-high pressure valves for hydrogen fueling stations and cryogenic valves for liquid hydrogen. Mt.H developed its hydrogen flow control valve in 2021 and supplied valves to a hydrogen station in Korea in 2022. LIMANNTECH supplies genuine Mt.H hydrogen valves.
Request a quotationContact us
Gas hydrogen valves, up to 99.9 MPa
| Model | Valve | Connection | Temperature |
|---|---|---|---|
| HV-CO | Flow control valve | 1/4", 3/8", 9/16", 3/4" tube | -40 to 85 °C |
| HV-ST-02 | Low temperature flow stop valve | 1/4", 3/8", 9/16", 3/4" tube | -40 to 85 °C |
| HV-ST-01 / HV-ST-01-CA | Flow stop valve, standard / cartridge | 1/4", 3/8", 9/16", 3/4" tube | -40 to 85 °C |
| HV-CH-01 | Line check valve | 1/4" to 1" tube | -40 to 85 °C |
| HV-ST (filter) | Filter, from 2 μm | 1/4", 3/8", 9/16", 3/4" tube | -40 to 85 °C |
Fluids: gas hydrogen, He, O2, N2, CO2, CH4, NH3.
Liquid hydrogen valves, up to 2.0 MPa
| Model | Valve | Size | Temperature |
|---|---|---|---|
| HV-EV | Emergency shut-off valve | DN 25, 32, 50 · PN 25 | -253 to 85 °C |
| HV-CH-02 | Lift check valve | DN 10, 15, 25 · PN 40 | -253 to 85 °C |
| HV-SV-02 | Conventional safety relief valve | 1" x 1" | -253 to 85 °C |
Fluids: liquid hydrogen, LNG, LPG, LN2, LAr, LO2.
Supply record
- 2021: hydrogen flow control valve developed
- 2022: valves supplied to a hydrogen station in Korea
- 2023: liquid hydrogen safety, check and emergency shut-off valves developed
- 2024: top prize in the H2 Innovation Award for the hydrogen flow control valve
- Installed at hydrogen fueling stations across Korea, including Incheon Airport T1, Samcheok, Jeonju, Daejeon and Yeosu
How to order
Send the details
Model number, size, pressure class, fluid, set pressure (for safety valves), material, and the nameplate photo or tag number if it is a replacement.
Quotation in 24 hours
We check the specification against the Mt.H catalogue and drawings and reply within one working day.
Delivery
To vessels and sites in Korea, or worldwide by air and sea freight.
FAQ
What pressure are the gas hydrogen valves rated for?
Up to 99.9 MPa (999 bar), for 70 MPa class fueling stations.
Are valves for liquid hydrogen available?
Yes: emergency shut-off, lift check and safety relief valves for -253 °C service up to 2.0 MPa.
More Mt.H Control Valves products
Cryogenic Safety Relief ValvesPilot operated and spring loaded
Cryogenic Control Valves-196 °C, Class 150 to 2500
ASME Safety ValvesASME UV stamp, SC32 and SP32
Gas & Fuel Supply SystemFGSS valves, valve trains