Brands / Mt.H Control Valves / Hydrogen Valves
Mt.H Control Valves · Genuine supply

Mt.H Hydrogen Valves – 99.9 MPa Gas and Liquid Hydrogen

Ultra-high pressure valves for hydrogen fueling stations and cryogenic valves for liquid hydrogen. Mt.H developed its hydrogen flow control valve in 2021 and supplied valves to a hydrogen station in Korea in 2022. LIMANNTECH supplies genuine Mt.H hydrogen valves.

Request a quotationContact us
Mt.H gas valve train and hydrogen flow control valve
Gas hydrogenUp to 99.9 MPa (999 bar)
Liquid hydrogen-253 °C, up to 2.0 MPa
MaterialStainless steel
Tube size1/4" to 1"

Gas hydrogen valves, up to 99.9 MPa

ModelValveConnectionTemperature
HV-COFlow control valve1/4", 3/8", 9/16", 3/4" tube-40 to 85 °C
HV-ST-02Low temperature flow stop valve1/4", 3/8", 9/16", 3/4" tube-40 to 85 °C
HV-ST-01 / HV-ST-01-CAFlow stop valve, standard / cartridge1/4", 3/8", 9/16", 3/4" tube-40 to 85 °C
HV-CH-01Line check valve1/4" to 1" tube-40 to 85 °C
HV-ST (filter)Filter, from 2 μm1/4", 3/8", 9/16", 3/4" tube-40 to 85 °C

Fluids: gas hydrogen, He, O2, N2, CO2, CH4, NH3.

Liquid hydrogen valves, up to 2.0 MPa

ModelValveSizeTemperature
HV-EVEmergency shut-off valveDN 25, 32, 50 · PN 25-253 to 85 °C
HV-CH-02Lift check valveDN 10, 15, 25 · PN 40-253 to 85 °C
HV-SV-02Conventional safety relief valve1" x 1"-253 to 85 °C

Fluids: liquid hydrogen, LNG, LPG, LN2, LAr, LO2.

Supply record

  • 2021: hydrogen flow control valve developed
  • 2022: valves supplied to a hydrogen station in Korea
  • 2023: liquid hydrogen safety, check and emergency shut-off valves developed
  • 2024: top prize in the H2 Innovation Award for the hydrogen flow control valve
  • Installed at hydrogen fueling stations across Korea, including Incheon Airport T1, Samcheok, Jeonju, Daejeon and Yeosu

How to order

1

Send the details

Model number, size, pressure class, fluid, set pressure (for safety valves), material, and the nameplate photo or tag number if it is a replacement.

2

Quotation in 24 hours

We check the specification against the Mt.H catalogue and drawings and reply within one working day.

3

Delivery

To vessels and sites in Korea, or worldwide by air and sea freight.

FAQ

What pressure are the gas hydrogen valves rated for?

Up to 99.9 MPa (999 bar), for 70 MPa class fueling stations.

Are valves for liquid hydrogen available?

Yes: emergency shut-off, lift check and safety relief valves for -253 °C service up to 2.0 MPa.

More Mt.H Control Valves products

Need an Mt.H valve or spare part for an LNG carrier, a gas-fuelled ship or a plant?sales@limanntech.com · +82-51-989-0101 · ShipServ TNID 261598
Send RFQ